- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Maity, Akash_Kumar (1)
-
Nayar, Shree_K (1)
-
Sabharwal, Ashutosh (1)
-
Wang, Jian (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
& Arya, G. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Camera-based heart rate measurement is becoming an attractive option as a non-contact modality for continuous remote health and engagement monitoring. However, reliable heart rate extraction from camera-based measurement is challenging in realistic scenarios, especially when the subject is moving. In this work, we develop a motion-robust algorithm, labeled RobustPPG, for extracting photoplethysmography signals (PPG) from face video and estimating the heart rate. Our key innovation is to explicitly model and generate motion distortions due to the movements of the person’s face. We use inverse rendering to obtain the 3D shape and albedo of the face and environment lighting from video frames and then render the human face for each frame. The rendered face is similar to the original face but does not contain the heart rate signal; facial movements alone cause pixel intensity variation in the generated video frames. Finally, we use the generated motion distortion to filter the motion-induced measurements. We demonstrate that our approach performs better than the state-of-the-art methods in extracting a clean blood volume signal with over 2 dB signal quality improvement and 30% improvement in RMSE of estimated heart rate in intense motion scenarios.more » « less
An official website of the United States government
